Please email us at [email protected] with our item No, NDC#, UPC# or the product link if you have any quetions. We are located in Oceanside, California. Search over 110,000 items by Name, Item No., NDC, UPC (without dashes) or by Mfg.Name. Please note, Prescription items can only be ordered by a Drug Manufacturer, Wholesaler, Hospital, Governmental Medical Facility, VA, Pharmacy, Physician, Physician Assistant, Nurse Practitioner, Dentist, Podiatrist, Optometrist, Veterinarian, Naturopath, Licensed Lab, Physical Therapist & Pharmacist in their scope of practice. No order will ship, unless you you have provided us the Medical License (and DEA Lic. in case of controlled drug) and we had verified that. Rx items can only be shipped to AZ, AR, CA, CT, DE, FL, GA, GU, HI, IL, KS, KY, LA, ME, MA, MI, NJ, NY, PA, PR, TX, TN, VA, WA, WI and WV. If you are an International Physician or Pharmacist, please contact us before ordering.


Visit AmericanPharmaWholesale.com for over 100,000 items of Health & Beauty at Retail@Wholesale prices.Bardex I.C. Foley Catheter 18Fr 5cc Item No.M-Ba1758Si18 Supplier:Bard Subcategory:Ur-Fo-Sv-18-5-2N<Br><Br>Item Description:Foley Catheter, All Silicone, 2-Way, 5Cc, 18Fr, 12/Cs<Br>Mfr. Item Code:1758Ur-Fo-Sv-18-5-2 N

Bardex I.C. Foley Catheter 18Fr 5Cc

$55.00$31.61

Item No.:M-BA1758SI18 Bardex I.C. Foley Catheter 18Fr 5cc Item No.M-Ba1758Si18 Supplier:Bard Subcategory:Ur-Fo-Sv-18-5-2N

Item Description:Foley Catheter, All Silicone, 2-Way, 5Cc, 18Fr, 12/Cs
Mfr. Item Code:1758Si18
Supplier Item Code:Bar 1758Si18
Unit Of Measure:Cs
Weight (Pounds):0.0000
Product Type:NDC Warehouse
Availability:
See Disclaimer Below.
Warehousestock Statusqty Availabledate Available
Lavergne, Tnnon Stocked 14-21 Days
See All Bard Medical/Ur

Have a question?

LUBRI-SIL� I.C. Infection Control Foley Catheters

The LUBRI-SIL� I.C. antimicrobial 100% silicone Foley catheter incorporates a technologically advanced formulation consisting of BACTI-GUARD�* silver alloy coating and BARD� hydrogel. The coating on the LUBRI-SIL� I.C. Foley catheter is designed to minimize biofilm formation and enhance patient comfort. In vitro testing of bacterial adherence demonstrates that the LUBRI-SIL� I.C. Foley catheter with BACTI-GUARD�* silver alloy coating and BARD� hydrogel reduces adhesion of the bacteria most commonly associated with catheter-associated urinary tract infections (CAUTIs)



PRESCRIPTIVE INFORMATION FOR FOLEY CATHETERS, DRAINAGE BAGS AND URINE METERS

INDICATIONS FOR USE: For urological use only.

CAUTIONS

� Federal (U.S.A.) law restricts this device to sale by or on the order of a physician.

� Do not aspirate urine through drainage funnel wall.

� Some Foley catheters may contain Natural Rubber Latex which may cause allergic reactions. Please check package.

� Contains or Presence of Phthalates: Di(2-ethylhexyl)phthalate (DEHP) is a plasticizer used in some polyvinyl chloride

medical devices. DEHP has been shown to produce a range of adverse effects in experimental animals, notably liver

toxicity and testicular atrophy. Although the toxic and carcinogenic effects of DEHP have been well established in

experimental animals, the ability of this compound to produce adverse effects in humans is controversial. There is no

evidence that neonates, infants, pregnant and breast feeding women exposed to DEHP experience any related adverse

effects. However, a lack of evidence of causation between DEHP-PVC and any disease or adverse effect does not mean that

there are no risks.

� With Temperature-Sensing Probes, in the presence of RF energy sources, local heating, temperature errors, and probe

damage may occur. In medical use, unplug the temperature-sensing catheter at the temperature monitor before activating

electrosurgical or other types of direct coupled RF energy sources. Do Not Stretch Catheter. This will cause repositioning of

the probe. Do not use Stylet. This will cause stretching of catheter.

WARNINGS

� On catheter, do not use ointments or lubricants having a petrolatum base. They will damage latex and may cause balloon

to burst.

� After use, this product may be a potential biohazard. Handle and dispose of in accordance with accepted medical practice

and applicable local, state and federal laws and regulations.

� Visually inspect the product for any imperfections or surface deterioration prior to use. Use Luer tip syringe to inflate with

stated mL of sterile water OR for pre-filled products, remove clip and squeeze reservoir to inflate with stated mL of sterile

water.

� Store catheters at room temperature away from direct exposure to light, preferably in the original box.

Visit AmericanPharmaWholesale.com for over 100,000 items of Health & Beauty at Retail@Wholesale prices.
AmericanPharmaWholesale.com
Visit AmericanPharmaWholesale.com for over 100,000 items of Health & Beauty at Retail@Wholesale prices.

Bardex I.C. Foley Catheter 18Fr 5cc Item No.M-Ba1758Si18 Supplier:Bard Subcategory:Ur-Fo-Sv-18-5-2N<Br><Br>Item Description:Foley Catheter, All Silicone, 2-Way, 5Cc, 18Fr, 12/Cs<Br>Mfr. Item Code:1758
Bardex I.C. Foley Catheter 18Fr 5Cc
Bardex I.C. Foley Catheter 18Fr 5cc Item No.M-Ba1758Si18 Supplier:Bard Subcategory:Ur-Fo-Sv-18-5-2N

Item Description:Foley Catheter, All Silicone, 2-Way, 5Cc, 18Fr, 12/Cs
Mfr. Item Code:1758

Ur-Fo-Sv-18-5-2 N
Bard
Ur-Fo-Sv-18-5-2 N