Please email us at [email protected] with our item No, NDC#, UPC# or the product link if you have any quetions. We are located in Oceanside, California. Search over 110,000 items by Name, Item No., NDC, UPC (without dashes) or by Mfg.Name. Please note, Prescription items can only be ordered by a Drug Manufacturer, Wholesaler, Hospital, Governmental Medical Facility, VA, Pharmacy, Physician, Physician Assistant, Nurse Practitioner, Dentist, Podiatrist, Optometrist, Veterinarian, Naturopath, Licensed Lab, Physical Therapist & Pharmacist in their scope of practice. No order will ship, unless you you have provided us the Medical License (and DEA Lic. in case of controlled drug) and we had verified that. Rx items can only be shipped to AZ, AR, CA, CT, DE, FL, GA, GU, HI, IL, KS, KY, LA, ME, MA, MI, NJ, NY, PA, PR, TX, TN, VA, WA, WI and WV. If you are an International Physician or Pharmacist, please contact us before ordering.


Rx Item-Carbidopa USP 500gm By Letco Medical

Carbidopa, USP 500gm By Letco Medical Item No.Letco610858 NDC No. 62991-2848-03 62991284803 Category: Rx This Prescription Item Can Only Be Ordered By Physicians, Pharmacies, Dentists, Wholesalers, HoJust change the quantity and save!Visit AmericanPharmaWholesale.com for over 100,000 items of Health & Beauty at Retail@Wholesale prices.COMPOUNDING ITEMS SPECIALIST

Rx Item-Carbidopa USP 500gm By Letco Medical

$39750.00$19872.67

Item No.:RX-LETCO610858, Carbidopa, USP 500gm By Letco Medical Item No.Letco610858 NDC No. 62991-2848-03 62991284803 Category: Rx This Prescription Item Can Only Be Ordered By Physicians, Pharmacies, Dentists, Wholesalers, Hospitals, Government, Va, Physician Assistants, Nurse Practitioners , Podiatrists, Opticians, Optometrists, Veterinarians, Naturalists, Licensed Labs, Physical Therapists & Pharmacists In Their Scope Of Practice. UPC No.: 96301036002900

Have a question?

CARBIDOPA, USP 500GM by Letco Medical Safety Data Sheet Section 1: Identification Common Name/Trade Name CARBIDOPA USP Supplier Information Letco Medical, LLC 1316 Commerce Drive NW Decatur, AL 35601 1 (800) 239-5288 +1 (734) 843-4693 IN CASE OF EMERGENCY: Chemtrec 1 (800) 424-9300 (24 hours) Product Synonym(s) Carbidopa hydrate Relevant Use(s) of Product Manuf acture or Compounding of Substances Section 2: Hazards Identification Classification of Substance or Mixture Serious eye damage/eye irritation (Category 2B) Signal Word Warning Hazard Statement(s) H320 Causes eye irritation Pictogram(s) N/A Precautionary Statement(s) P264 Wash hands thoroughly af ter handling. P305+P351+P338 IF IN EYES Rinse cautiously with water f or several minutes. Remove contact lenses if present and easy to do. continue rinsing. P337+P313 If eye irritation persists Get medical advice/attention. Hazards Not Otherwise Classified No data available Ingredient(s) with Unknown Toxicity No data Available Section 3: Composition/Information on Ingredients Chemical Name Benzenepropanoic acid, alpha-hydrazino-3,4-dihydroxy-alpha-methyl-, monohydrate, (S) Common Name Carbidopa CAS Number 38821-49-7 Impurities and/or Stabilizing Additives No data available Section 4: First Aid Measures General Advice Remove from exposure. Remove contaminated clothing. For treatment advice, seek guidance from an occupational health physician or other licensed health-care provider f amiliar with workplace chemical exposures. In the United States, the national poison control center phone number is 1-800-222-1222. If person is not breathing, give artif icial respiration. If breathing is dif f icult, give oxygen if available. Persons developing serious hypersensitivity (anaphylactic) reactions must receive immediate medical attention. If Inhaled Move to fresh air. Call a physician if symptoms develop or persist. In Case of Skin Contact Rinse skin with water/shower. Get medical attention if irritation develops and persists. In Case of Eye Contact Remove contact lenses , if present and easy to do. Continue rinsing. Get medical attention if irritation develops and persists. If Swallowed Rinse mouth. If ingestion of a large amount does occur, call a poison control center immediately. Most Important Symptoms and Effects Irritation of eyes and mucous membranes. Section 5: Fire Fighting Measures Suitable Extinguishing Media Water. Foam. Dry chemical or CO2. Special Hazards Arising From the Substance/Mixture No unusual f ire or explosion hazards noted. Special PPE and/or Precautions for Firefighters Wear suitable protective equipment. Use water spray to cool unopened containers. As with all f ires, evacuate personnel to a saf e area. Firef ighters should use self-contained breathing equipment and protective clothing. Page 1 of 4 Section 6: Accidental Release Measures Personal Precautions, Protective Equipment and Emergency Procedures Keep unnecessary personnel away. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Ensure adequate ventilation. Avoid inhalation of dust from the spilled material. Wear appropriate personal protective equipment. Methods and Materials Used for Containment Sweep up or vacuum up spillage and collect in suitable container f or disposal. Avoid the generation of dusts during clean-up. Clean surf ace thoroughly to remove residual contamination. Cleanup Procedures Sweep up or vacuum up spillage and collect in suitable container f or disposal. Avoid the generation of dusts during clean-up. Clean surf ace thoroughly to remove residual contamination. Section 7: Handling and Storage Precautions for Safe Handling As a general rule, avoid all contact and inhalation of dust, mist, and/or vapors associated with the material. Clean equipment and work surf aces with suitable detergent or solvent af ter use. Af ter removing gloves, wash hands and other exposed skin thoroughly. Conditions for Safe Storage Store in tight container as def ined in the USP-NF. This material should be handled and stored per label instructions to ensure product integrity. Section 8: Exposure Controls/Personal Protection Components with Workplace Control Parameters No biological exposure limits noted f or the ingredient(s). No exposure standards allocated. Appropriate Engineering Controls Airborne exposure should be controlled primarily by engineering controls such as general dilution ventilation, local exhaust ventilation, or process enclosure. Local exhaust ventilation is generally pref erred to general exhaust because it can control the contaminant at its source, preventing dispersion into the work area. An industrial hygiene survey involving air monitoring may be used to determine the ef f ectiveness of engineering controls. Ef f ectiveness of engineering controls intended f or use with highly potent materials should be assessed by use of nontoxic surrogate materials. PPE - Eye/Face Protection Saf ety glasses with sideshields are recommended. Face shields or goggles may be required if splash potential exists or if corrosive materials are present. Approved eye protection (e.g. bearing the ANSI Z87 or CSA Stamp) is pref erred. Maintain eyewash f acilities in the work area. PPE - Skin Protection Hand protection: Chemically compatible gloves. For handling solutions, ensure that the glove material is protective against the solvent being used. Use handling practices that minimize direct hand contact. Employees who are sensitive to natural rubber (latex) should use nitrile or other synthetic nonlatex gloves. Use of powdered latex gloves should be avoided due to the risk of latex allergy. PPE - Body Protection For handling of laboratory scale quantities, a cloth lab coat is reccommended. Where signif icant quantities are handled, work clothing may be necessary to prevent take-home contamination. PPE - Respiratory Protection Where respirators are deemed necessary to reduce or control occupational exposures, use NIOSH-approved respiratory protection and have an ef f ective respirator program in place. (applicable U.S. regulation OSHA 29 CFR 1910.34). Section 9: Physical and Chemical Properties Appearance White to creamy white powder. Physical state: Solid. Form: Powder. Upper/Lower Flammability or Explosive Limits No data available Odor Odorless or practically odorless Vapor Pressure No data available Odor Threshold No data available Vapor Density No data available pH 4 - 6 (91% suspension) Relative Density No data available Melting Point/Freezing Point Melting point/freezing point: 397.4-406.4�F (203-208�C) (decomposes) Solubility Slightly soluble in water. Initial Boiling Point and Boiling Range No data available Flash Point No data available Evaporation Rate No data available Flammability (Solid, Gas) Not applicable. Partition Coefficient No data available Auto-Ignition Temperature No data available Decomposition Temperature No data available Viscosity No data available Page 2 of 4 Section 10: Stability and Reactivity Reactivity No reactivity hazards known. Chemical Stability Stable at normal conditions. Possibility of Hazardous Reactions No dangerous reaction known under conditions of normal use. Conditions to Avoid None known. Incompatible Materials Strong oxidizing agents. Hazardous Decomposition Products Irritating and/or toxic f umes or gases. Emits toxic f umes under f ire conditions. Section 11: Toxicological Information Acute Toxicity - LD50 Oral LD50 Mouse 1750 mg/kg, Rat 4810 mg/kg Acute Toxicity - Inhalation Due to lack of data the classif ication is not possible. Acute Toxicity - Dermal Due to lack of data the classif ication is not possible. Acute Toxicity - Eye Causes eye irritation Skin Corrosion/Irritation Based on available data, the classif ication criteria are not met. Serious Eye Damage/Irritation Causes eye irritation. Respiratory or Skin Sensitazation Due to lack of data the classif ication is not possible. Germ Cell Mutagenicity Due to lack of data the classif ication is not possible. Carcinogenicity IARC Due to lack of data the classif ication is not possible. Carcinogenicity ACGIH Due to lack of data the classif ication is not possible. Carcinogenicity NTP Due to lack of data the classif ication is not possible. Carcinogenicity OSHA Due to lack of data the classif ication is not possible. Reproductive Toxicity Due to lack of data the classif ication is not possible. Specific Target Organ Toxicity - Single Exposure Due to the lack of data the classif ication is not possible. Specific Target Organ Toxicity - Repeated Exposure Due to lack of data the classif ication si not possible. Aspiration Hazard Based on available data, the classif ication criteria are not met. Section 12: Ecological Information Toxicity Acute: Crustacea LC50 Daphnia magna >8.4 mg/l Persistence and Degradability No data is available on the degradability of this product. Bio-accumulative Potential No data available Mobility in Soil No data available Other Adverse Effects No data available Section 13: Disposal Considerations Waste Treatment Methods Product Dispose of in accordance with local regulations. Empty containers or liners may retain some product residues. This material and its container must be disposed of in a saf e manner. Under RCRA, it is the responsibility of the user of the product to determine, at the time of disposal, whether the product meets RCRA criteria f or hazardous waste. Waste Treatment Methods Packaging Empty containers should be take to an approved waste handling site f or recycling or disposal. Since emptied containers may retain product residue, f ollow label warnings even af ter container is emptied. Special Precautions Landfill or Incinerations No data available Other Information No data available Section 14: Transport Information UN Number Not dangerous goods UN Proper Shipping Name N/A Transport Hazard Class(es) N/A Packaging Group N/A Environmental Hazards N/A Page 3 of 4 Section 15: Regulatory Information US Federal regulations: CERCLA/SARA Hazardous Substances - Not applicable. One or more components are not listed on TSCA. Superf und Ammendments and Reauthorization Act of 1986 (SARA): Hazard categories: Immediate Hazard-Yes, Delayed Hazard-No, Fire Hazard-No, Pressure Hazard-No, Reactivity Hazard-No. SARA 302 Extremely hazardous substance: No. SARA 311/312 Hazardous chemical: Yes. Other f ederal regulations: Saf e Drinking Water Act (SDWA): Not regulated. Food and Drug Administration (FDA): Not regulated. US state regulations: Calif ornia Saf e Drinking Water and Toxic Enf orcement Act of 1986 (Proposition 65): This material is not known to contain any chemicals currently listed as carcinogens or reproductive toxins. International Inventories: Country(s) or region/Inventory Name/On Inventory (yes/no)*: Australia, Australian Inventory of Chemical Substances (AICS), No. Canada, Domestic Substances List (DSL), No. Canada, Non-Domestic Substances List (NDSL), No. China, Inventory of Existing Chemical Substances in China (IECSC), No. Europe, European Inventory of Existing Commercial Chemical Substances (EINECS), No. Europe, European List of Notif ied Chemical Substances (ELINCS), No. Japan, Inventory of Existing and New Chemical Substances ( ENCS), No. Korea, Existing Chemicals List (ECL), No. New Zealand, New Zealand Inventory, No. Philippines, Philippine Inventory of Chemicals and Chemical Substances (PICCS), No. United States & Puerto Rico, Toxic Substances Control Act (TSCA) Inventory, No. *A "Yes" indicates that all components of this product comply with the inventory requirements administered by the governing country(s). Section 16: Other Information Additional Information Prepared By Lisa Russell Revision Date 01/14/2019 17:12 Disclaimer Letco Medical, LLC believes that the above information is correct but does not purport to be all inclusive and shall be used only as a guide. The information in this document is based on the present state of our knowledge and is applicable to the product with regard to appropriate safety precautions. If the product is used as a component in another product, this information may not be applicable. NO WARRANTY OF FITNESS FOR ANY PARTICULAR PURPOSE, WARRANTY OF MERCHANTABILITY OR ANY OTHER WARRANTY, EXPRESSED OR IMPLIED, IS MADE CONCERNING THE INFORMATION PROVIDED ABOVE. Letco Medical shall not be held liable for any loss or damage resulting from handling, storage, use or from contact with the above product. Page 4 of 4

Carbidopa, USP 500gm By Letco Medical Item No.Letco610858 NDC No. 62991-2848-03 62991284803 Category: Rx This Prescription Item Can Only Be Ordered By Physicians, Pharmacies, Dentists, Wholesalers, Ho
CARBIDOPA, USP 500GM by Letco Medical
Carbidopa, USP 500gm By Letco Medical Item No.Letco610858 NDC No. 62991-2848-03 62991284803 Category: Rx This Prescription Item Can Only Be Ordered By Physicians, Pharmacies, Dentists, Wholesalers, Ho

Just change the quantity and save!
Buy more Save More!
Just change the quantity and save!

Visit AmericanPharmaWholesale.com for over 100,000 items of Health & Beauty at Retail@Wholesale prices.
AmericanPharmaWholesale.com
Visit AmericanPharmaWholesale.com for over 100,000 items of Health & Beauty at Retail@Wholesale prices.

COMPOUNDING ITEMS SPECIALIST
LETCO MEDICAL
COMPOUNDING ITEMS SPECIALIST